  • Maintenance and management instruction for PV mounting system

    General

    PV mounting system can be divided into ground system, roof system, façade, BIPV, etc, which need to be checked, maintained and protected at certain frequency so as to ensure its good performance.

    Maintenance and management system

    1 Staffing

    Professional maintaining team need to be set up to provide services for planned and emergent maintenance.

    2 Tools for maintenance (Refer to Annex 1)

    3 Preparation for materials of ordinary maintenance (Refer to Annex 2)

    4 Institutions

    4.1Maintenance reporting system need to be established to report the maintenance plan

    4.1.1plan for ordinary checking and maintenance

    In order for the reliability and safety of the PV systems, ordinary checking and maintenance will be needed at the frequency of at least once per month.

    Sample form for ordinary checking (Refer to Annex 3)

    4.1.2 Checking and maintenance after harsh weather conditions

    Checking and maintenance need to be taken after such harsh weather conditions as storm above 6 degrees, tropical storm, snow and earthquake, and records need to be made accordingly. Reports need to be submitted for dealing with damages.

    4.1.3 Annually routine checking and maintenance

    This action ensures the reliable operation of the PV systems. Specific and detailed annual maintenance plan need to be made according to the annually routine checking and maintenance guidance provided by suppliers and actual condition with the principle of prevention and planned checking.

    Sample form for routine checking (Refer to Annex 4)

    4.1.4 Report for annual maintenance

    The maintaining team should summarize the problems emerged during the maintenance around the year and report to the company or manufacturer.

    4.1.5 Method for dealing with general problems (Refer to Annex 5)

    Report need to be submitted to company or manufacturer regarding the checking and maintenance result.

    4.1.6 System for registry and signature

    Registry and signature by checking person need to be recorded.

    5 Safety rules

    Checking and maintenance for the mounting system higher than 2.5m should be undertaken strictly according to the following rules:

    5.1 Special clothes and safety belt will be needed.

    5.2 Safety helmet and other protection measures will be required for the maintaining staff.

    5.3 checking and maintenance should be prohibited under storms with the degree above 4, rain and snow, and night without lighting.

    5.4 No smoking and drinking will be allowed during checking and maintenance.



    Annex 1:

    No.DescriptionUnitQtyRemark
    1pile driveset1
    2motor-drive wrenchpiece1
    3Open ring wrenchpiece210*12
    4Open ring wrenchpiece26*8
    5Adjustable wrenchpiece2100×13
    6Tape measurepiece17.5m*25mm
    7Rulepiece11m不锈钢
    8Angle squarepiece1L=500mm
    9Level rulepiece1L=1000mm
    10soft pipepiece120
    11Hammerpiece2木柄圆头,5磅
    12internal hexagonal box-end wrenchpiece2M6
    13internal hexagonal box-end socketpiece217mm
    14Markerpiece2
    15Long nose plierspiece1
    16shearsset1
    17building draw line toolsset1
    Back to top

    Annex 2:

    No.ItemUnitQtyRemarks
    1Screw boltset100can be adjusted according to specific requirements
    2Mounting kitset1
    3Zinc rich epoxy primerkg10
    Back to top

    Annex 3:

    ItemChecking DetailsTimeResult
    Chemical boltWhether the chemical bolt is loosening or notyes
    no
    Splice kitWhether the screw bolt is loosening or notyes
    no
    ClampWhether the screw bolt is loosening or notyes
    no
    ModuleWhether the modules are flat and of the same inclination degreesyes
    no
    Mounting kitWhether the mounting kit is deformedyes
    no
    Back to top

    Annex 4:

    ItemChecking DetailsFrequencyResult
    Chemical boltWhether the chemical bolt is loosening or notannuallyyes
    no
    Splice kitWhether the screw bolt is loosening or not, whether the splice kit is deformed or notannuallyyes
    no
    ClampWhether the screw bolt is loosening or not, whether the clamp is deformed or notannuallyyes
    no
    ModuleWhether the modules are flat and of the same inclination degreesannuallyyes
    no
    Mounting kitWhether the mounting kit is deformed, whether the mounting kit gets rusty or notannuallyyes
    no
    Back to top

    Annex 5:

    ItemProblemsMethod
    Chemical boltWhether the chemical bolt is loosening or not1. The quality of concrete need to be improved and the concrete foundation need to be changed if the problem goes to the strength of the foundation. Screw bolt or the chemical agent need to be changed if there is problem with the screw bolt itself.
    Screw boltWhether the chemical bolt is loosening or not1. Re tighten the screw bolts.
    2. Change the supplier.
    Clampwhether the clamp is deformed or not1. Re install the clamps.
    ModuleWhether the modules are flat and of the same inclination degrees1. Mounting kit need to be changed or reformed.
    2. Adjust the mounting kit into the same level.
    Mounting kitwhether the mounting kit gets rusty or not1. Mounting kit should be handled with care so as to protect the hot dip zinc layer. Crash should be avoid during installation.
    2. zinc rich epoxy primer should be painted once the hot dip zinc layer is damaged with the thickness of no less than 120μm. Once the mounting kit get rusty, sand paper can be used to clean the rust and zinc rich epoxy primer or other protection painting material can be used later after the cleaning.
    Back to top